Products
Your current location: Home > Products > Other Products
- Introduction
- Type
- Features
- Parameter
- Case
HT-ITGC network intelligent anti robbery system controller connected to the control center tear through the network, while the connection is equipped with tear gas bombs mounting box. The controller may control the initiation site, can also be remote control detonator, while loud alarm sound when detonated. Emergency Press both start button on the controller, you can detonate tear gas bombs; when the control center duty officer found wrongdoing by the monitor screen (such as the destruction ATM machine, grab the customer, etc.), the situation is critical, to be started immediately burst tear gas, the duty officer immediately remotely detonate tear gas bombs.
● control panel with a battery backup in case of power failure state, can be used continuously for more than 10 days
● 8-way tear gas transmission interface
● alarm output interface
● tamper switch interface controller tamper alarm
● Controller disarming switch lock
● Local two-button control of the first road tear gas emission, central remote control 8 tear gas emission
● Ethernet interface to connect the control center to receive the central control, transmission control information
● mains outage detection, power report Recovery Report
● Battery voltage low detection, low report
● Battery over-discharge protection
● AC-DC power supply automatic conversion
● tear gas to control the line break alarm
● store 100 event records, comprising: a mains failure and recovery, battery voltage detection, tear gas was cut, tear gas emission, tamper, arming and disarming
No. | Project | The main technical parameters |
1 | Connection | 1 RJ45 10 / 100M adaptive Ethernet interface connected to the network |
2 | Tamper | A tamper switch interfaces, tamper alarm |
3 | Siren | An alarm interface and alarm output DC12V voltage drive siren alarm |
4 | Arm and disarm | An arm and disarm switch lock, switch closure arm, disarm disconnect, turn control armed state |
5 | Instruction | A power light, a Ready light indicates the armed state, an enabled LED indicates the device starts |
6 | Start button | A, B start at left and right buttons, arming state, and press the start of the first path tear gas explosion |
7 | Remote control | 8-way remote control to start the tear gas explosion, dongle authorization confirmation |
8 | Battery | A DC12V battery connector, AC / DC automatic conversion |
9 | Power supply | 1 AC220V, 50z Power Interface |
10 | Product Size | 270×270×75mm |
11 | Temperature | 0~55℃ |
12 | Humidity | 10~90% |