Hengtong HT-DCU2000 access control system through a card reader or fingerprint identification door opening controlled by the controller, the controller can be directly connected to control two doors, connecting through 485 single door, double door control module. A controller can be connected to control 64 doors, the management center through the network connection controller, receiving controller action, alarms, etc., while the remote control door lock operation.
 
HT-DCU2000-LS64 Access Controller            HT-WG / 3B Reader          DCU2000-D2 Double Door Expansion Module
Product Name Product Type Explanation
Access Controller HT-DCU2000-LS04 Fi, a two-door extended to four control
HT-DCU2000-LS16 Fi, a two-door extended to 16 control
HT-DCU2000-LS64 Fi, a two-door extended to 64 control
Reader HT-WG/3B Wiegand 26 format, non-contact ID card reader data
Single Door Expansion Module DCU2000-DP1 485 connection controller, expand access, control gate 1
Two-door expansion modules DCU2000-D2 485 connection controller, the expansion connector, control 2 doors
Emergency control system HT-REMD Network remote control 8-way switching, telephone control switch movement
● Wiegand26 format card reader or fingerprint reader
● The controller is directly connected to control two-way door or a two-way door or anti-tail gate
● single door bi-directional control, a door can be set to any two-way card door
● Double Door mutual control settings can be set to any two doors anti-tail linkage interlock
● card with the password to open the door set, access group settings
● You can set 15 seven days a week schedule, four hours a day, 200 holiday controls
● lock automatically return to normal state after a period of time can be set door is always open, time to
● Each door, each with a door button, open the door for use from the inside out, the software can be set to prohibit the use of
● hijack code setting, kidnapped door alarm
● Controller tamper alarm
● fire linkage settings, press the emergency button to open the pre-fire linkage fire exits, close the isolation gate
● remote control management of emergency situations or when a controller of a sector-wide door opening and closing
● "double open" or "double close" button, an emergency force to turn the two doors connecting the controller
● keep all cardholder data 5000 and recorded 130,000 card readers and other events, cardholder and event records can be dynamically adjusted
● network connection system, transmission of data encryption, network time, so management center connected to the controller from the unlimited extension of unlimited expansion of the number of connections
● Each controller is connected directly to control two doors, connecting doors through RS485 bus extension module, control 4/16/64 door.
● alarm output, the controller provides three alarm output, various alarm integrated way, B1, B2 door all the way, independent of each door module provides one output
● multi-door mutual control to set how much anti-tail linkage door interlock function menu, only to open a door, open the door closed until after the order to open the other door
● Anti-passback setting, a few doors can be set to any anti-passback function, eight anti-submarine locale
● keyboard password controlled authorization, controlled authorization instructions, remote controlled authorization
● grouping scheme set up some special occasions in a period of time, you need to brush a few cards to open the door
● AC detection, power / recovery report
● DC detection, low voltage report
No. Project The main technical parameters
1 Reader Interface The controller 2 Wiegand 26 Reader Interface
2 Network Interface A RJ45 10 / 100M adaptive interfaces
3 Control the number of gates 4/16/64 door
4 Extended connection 485 connection, address jumpers recognition
5 Alarm Output The controller 3, the door module 1 Interface
6 Tamper The controller 1, a door module tamper switch interfaces, open action
7 Double Open button Controller 1 pair of open pushbutton interface, in-house operation
8 Pun Button Controller 1 pair off button interfaces, in-house operation
9 Fire linkage A fire linkage interface controller, closed-circuit action
10 Exit button One out of every door pushbutton interface, in-house operation
11 Magnetic Interface Each door is a door sensor interfaces, normally open check door status
12 Door lock control Every door a normally open / normally closed-door lock control interface
13 Restore Default Hardware jumper settings, restore factory default
14 Anti-tail Any two doors set
15 Multi-door mutual control 8 door, multi-door 8 Group mutual control settings
16 Two-way mutual control gate Optionally two doors set
17 Antisubmarine locale 8 anti-submarine locale
18 Controlled authorized Password keyboard controlled authorization, LED connector
19 Grouping scheme Eight scenarios, each four group settings
20 Holiday time zone 15 time zones, seven days a week 4 period, 200 holiday controls
21 Information Storage Action information is stored 130,000, user information is stored 5000
22 Board Size 95×110mm
23 Controller size 350×270×75mm
24 Power supply AC220V±20,50Hz, DC12V/7AH standby power, rated current 2A, DC input 5A
25 Power loss ≤5W
26 Work Environment Operating temperature: 0 ~ 50 ℃, relative humidity: ~90%