Products
Your current location: Home > Products > Access Control System
- Introduction
- Type
- Features
- Parameter
- Case
HT-ILC network-based anti-tail interlocking safety door interlock control system consists of front-end devices, the central management server and control the client software. Front-end equipment by the HT-ILP control panel is controlled by two doors HT-ILC controller, two doors in addition to the automatic interlocking, the control panel can control the inner door open, the outer door opened, two doors open simultaneously, the two doors at the same time Close not be opened, the control system is reset. HT-9502WV wall-mounted intercom host controller via a network connection, control security door door open, the outer door opened, two doors open simultaneously, the two doors can not be opened while closing, the control system is reset, call, intercom, display video.
HT-ILC controller central management server via a network connection, control client software through a central management server front-end device control, front-end equipment to receive information on the operation of the monitoring equipment. Control client software can run on the same plane with the central management server can also be separately installed.
HT-9502WV wall-mounted intercom host HT-ILP panel HT-LS04 Lock
Product Name | Product Type | Explanation |
Networked anti-tail linkage interlocked safety door controller | HT-ILC | Connecting door, control panel and connecting the control center |
Control Panel | HT-ILP | RJ45 interface controller, door lock control |
Lock | HT-SL04 | Connection readers, exit button, connect the controller 485 |
Wall-mounted intercom host | HT-9502WV | Wiegand 26 format, non-contact ID card reader data |
Reader | HT-WG/3B | Fi 7-inch touch screen control |
● anti-tail linkage interlock two doors, a door opens another door to open after closing
● Lock Wiegand26 format card reader or fingerprint reader Interface
● Lock out pushbutton interface
● Control panel buttons to open the inner door, inner door open individual control
● Control panel buttons to open the outer door, individually controlled outer door open
● Control Panel double-open button, emergency control double doors open, to form a channel
● Control Panel double off button, the special circumstances of the two doors at the same time until the lockout reset
● Control panel reset button, emergency lockout reset
● Control Panel Network intercom call button, call monitoring center through a network Hands-free intercom, reception centers monitoring, broadcasting
● Control panel RJ45 interface controller, intercom, voice communications
● Lock status indicator that locks work status
● inner door 485 bus controller address jumpers recognition, outside the door
● electronically controlled door locks, keys to open the latch
● door automatically locked, only the lock function
● tamper bolt in place detection, fault alarm
● through the LAN to Xia Zhu outlets, institutional anti-tail linkage interlocking safety door access to real-time status data transmission, inquiry
● real-time acquisition and accurate records of all open, door signal and the time of each control system sounds, including mechanical key under power, the Open button to open the door of the closed records.
No. | Project | The main technical parameters | |
1 | Manual version | HT-ILC V1.2 | |
2 | Lock control version | HT-SL01:HT-SLCU-S V1.1,HT-SL02 :HT-SLCU-S2 V1.0 | |
3 | Controller Board Revision | HT-ATMSCU V1.01 | |
4 | HT-ILP Dashboard version | HT-ILP:HT-ILP V1.0,HT-9502WV:HT-9502WV 1.0 | |
5 | Interface | Lock | An open button Interface |
6 | An 485 communication interface, connect the controller | ||
7 | A reader interface Wiegand26 | ||
8 | 1 DC12V Power Interface | ||
9 | A door sensor inputs | ||
10 | A lock status indicator of the interface (factory connection) | ||
11 | A motor control interface (factory connection) | ||
12 | A bolt door magnets interface (factory connection) | ||
13 | Controller | 1 DC12V Power Interface | |
14 | An 485 communication interface connecting door locks | ||
15 | An RJ45 interface HT-ILP Control Panel | ||
16 | An RJ45 network interface | ||
17 | Control Panel | An RJ45 interface controller | |
18 | HT-9502WV | An RJ45 network interface | |
19 | An DC12V Power Interface | ||
20 | Control buttons | One outside the open button, individually controlled open the outer doors | |
21 | An inner open button to open the inner door alone control | ||
22 | 1 pair of open button, press an emergency situation, control two-door open, form a channel | ||
23 | 1 pair of close button, press the special circumstances, while blocking two doors until reset. | ||
24 | A reset button to reset the locked state of emergency. | ||
25 | An intercom button and call monitoring center, answering the intercom (9502-WV display video). | ||
26 | 9502-WV: 1 door status inquiry, a Settings button | ||
27 | Power | Unlock | 10W |
28 | Standby | ≤60 mA | |
29 | Controller | ≤350 mA | |
30 | Product Size | Controller | 350×270×75mm |
31 | Lock | 170×95×35mm | |
32 | Control Panel | 182×86×20mm | |
33 | HT-9512WV | 211×155×45mm | |
34 | Working temperature | Temperature: 0 ℃ ~ 55 ℃, Humidity: 10%~95% |