HT-ATMSCU-4 bank self-protection device bay controller is the heart of the Smart Protection cabin, by 485 bus connection, control four guard door lock, and transmit information through the network to the monitoring center, the monitoring center to receive control information, comprehensive realization Getting control, keyless entry, voice prompts, door lock control, door control, high voltage control, alarm output, linkage output function.
● Network connection report controller operation information, real-time monitoring and control for remote control
● RS485 connection, control four smart locks, address jumpers recognition
● Controller tamper switch interfaces, open alarm
● Controller Interface siren sound and light alarm
● Controller AC, DC power source detection, automatic conversion, transmission status report
● automatic locking door, outside can not open, intelligent detection of 1.2 meters into the children, the door does not lock
● Smart detection collapsed into the personnel alarm
● Voice prompt, inform precautions and prevention requirements
● emergency alarm button, to the alarm monitoring center
● external speakers, play sound information
● out of the probe body
No. | Project | The main technical parameters |
1 | Network Interface | Motherboard RJ45 10 / 100M adaptive network interface |
2 | Communication Interface | Board locks, one each RS485 communication interface, door address jumpers recognition |
3 | Tamper Interface | A controller tamper interface to connect tamper switch open alarm |
4 | Power Output | A controller DC12V output, to provide power door locks |
5 | Siren output | An alarm controller interface alarm sound and light alarm |
6 | Set jumper | Controller output normally open, normally closed jumpers, set the output status |
7 | Power input | Controllers, door locks, one each DC12V input interface |
8 | Power Detection | Controller AC, DC detection interface for connection to the power supply board power supply detection port, detect power supply status |
9 | Exit button | A lock out pushbutton interface, short circuit open |
10 | Magnetic input | Lock a door sensor input interface to connect tamper switch detects door status |
11 | Fan Control | Lock a fan connector, automatically start the fan when the fan is connected to control entry into |
12 | Fluorescent lamp | Lock a fluorescent lighting control interface to access external relay start |
13 | Speaker Output | Lock a speaker output port, connected 8Ω5W tone horn player |
14 | Lock status lights | Two door lock status indicator of the interface, the factory has been connected to indicate lock status |
15 | Door button | A door exit button, short circuit open, protective compartment may not be connected |
16 | Curtain input | Lock a curtain input interface to connect curtain detector |
17 | Emergency button | Lock an emergency button interface short circuit alarm |
18 | Motor Control | Lock a motor control interface, the factory is connected |
19 | Electromagnet | A door lock solenoid bolt interface connection factory |
20 | Reader | Lock a card reader interface, without the use of protective cabin |
21 | Address Jumper | Address jumpers locks, door position identification |
22 | Product Size | Board Size 93 × 110mm, the controller size: 270 × 270 × 75mm |
23 | Working temperature | 0~55℃ |
24 | Working humidity | 10~90% |