DP1 door module as access control system extension module, transmitted via RS485 connection access control information to the controller, and the controller receives the operation instruction, a control module connected to a door.
No. Project Technical parameters and functions
1 Communication Connections RS485
2 Reader Interface A card reader interfaces, network connection Wiegand26 format card reader or fingerprint reader
3 DC Detection A DC detection interface for connection to the power board "DC Detection", the battery voltage is lower than 11.3V when prompted
4 AC Detection An AC detection interface for connection to the power board "AC Detection", indicating AC power failure and recovery time
5 Tamper control A tamper switch interface for connection to a normally closed switch, when enabled, the switch is open alarm. Two minutes after the restart the system is reset to take effect, brush withdrawal of police card to withdraw police alarm.
6 Lock output A lock output interface, the connection control normally open / normally closed-door lock
7 Buzzer A buzzer, ring tones
8 Controlled instruction Indicator light indicates when a controlled interface to connect controlled lights, door in a controlled state
9 Exit button An exit button interface to connect the home button, the closed door
10 Magnetic Interface A tamper switch interface to connect tamper switch detects door status
11 PIN Pad 1 channel password keyboard interface, enter the correct password, the switch is closed, the door controlled, controlled lights.
12 Alarm Output 1 normally open / normally closed alarm output interface
13 Address switch An address switch, set the door module address
14 Size 50×65mm
15 Power supply DC12V
16 Working temperature 0℃~50℃
17 Relative humidity 5~90%